|  |  | 
							 
								 | 
     
    
  
   |  | 
							 
								 |  |  | 
							 
						   
  
 | 
					 
				 
 | 
    
    
    
					
        
        
						
                
                    Ametek Jofra mACAL Loop Calibrator
  
  
    | 
          
      
                	 Item Number: MACAL 
                      	
                      Manufacturer: Ametek (JOFRA) 
                               
      	    Manufacturer Part No: MACAL 
    	           
                                 
                          
          	
                  
		      
     | 
    
                              
                                 |     
   
    
    
      Ametek Jofra mACAL Loop Calibrator 
    The mAcal Milliamp Loop Calibrator is an economical, easy to  use calibration device for generating and measuring mA signals.  The instrument is especially designed for 2-wire transmitter  loops with 4-20mA signals and it is available with optional   NIST certification.        The unit’s compact size and light weight is ideal for field use.  Dedicated functions keys located on the front of the device  allow for simple, single-hand operation. The keypad provides  positive feedback to the user and each key is labeled for easy  operation. A large, high-contrast, 5-digit LCD display indicates  numeric values in mA, %, V or sec. Resolution is 0.001mA  in measurement mode. The user can change the display to  read in % of Full Scale. Flow readings are shown in % of Flow.  The display also indicates error codes. Alarms may be displayed  showing loop mismatch, reverse polarity and overrange.  The unit will also display low battery notification message. Plus,  the unit is equipped with an automatic shut-off features that  prevents accidental battery discharge. A built-in, permanent fuse   eliminates the need to replace the fuse in the case of overloads.        The mAcal Loop Calibrator provides loop power control in the  range of 0-45V and the instrument may be used to generate a  stable 24Vdc supply for the loop. The mAcal Loop Calibrator also   reduces the time and complexity often associated with loop calibration.  The instrument features special fixed steps for performing linear and   flow transmitter or valve positioner calibrations. The instrument has  seven different built-in current values, and the user may choose  between manual and automatic steps with 10- or 30-seconds  between steps. For example, you can perform an entire test by  placing the mAcal Calibrator in the process loop and operating  from the control room. 
  
    The unit comes complete with the mAcal Calibrator, carrying  case, two test leads with alligator clips, four batteries (Type  LR6, AA) and a User's Guide. 
Features:        • Generates and Measures the Loop Current        • Stabilized 24Vdc Loop power        • Drives up to 900 Ohms         • Resolution of 0.001mA in Measurement Mode        • Change Display to Read % of Full Scale        • Special Fixed Steps stored for Linear and Flow Transmitters        • Choose between Manual and Automatic Steps        • Set 10 to 30-seconds between Steps        • Available with Optional NIST Certification   
  Specifications:       
   
     | 
   
   
		
                 
                
                
                
                
            
					 
        
        
    
				 
    
					
    
    
				 
 | 
			 
		  |