                    Hart Scientific 1522 Standard Logging Thermometer
  
    |  | 
                          OUR PRICE: This unit has been discontinued. Please call (732) 632-6400 for replacement options Item Number: 1522 
                      Manufacturer: Hart Scientific Manufacturer Part No: 1522 |  
    | Hart Scientific 1522 Standard The Models 1522 is the first standards thermometers toThermometer
fit into a battery-powered handheld package. It as accurate as ±0.005°C!
 You'll only find this level of accuracy in large desktop units that cost three times
 more.  It's no wonder we call it the Little Lord Kelvin of thermometry.
 Fitting easily into your hand and weighing only 1 pound (0.4 kg), these
 thermometers can go anywhere.  And when they get there, you can have
 total confidence in the accuracy of your measurements.  The 1522 has the
 power of a full data logger, with memory to hold 10,000 readings.
 Features 
    
Reads PRTs/RTDs to ±0.025°C and thermistors to ±0.005°C Model 1522 stores multiple data sets totaling 10,000 readings INFO-CON connector allows interchangeable use of calibrated probes INFO-CON eliminates errors from programming probe data  
    
      
        
| Specifications   |  
        
| Sensor Type | Pt 25 to Pt 100   | Thermistor   |  
        
| Temperature Range   | –200°C to 962°C   | –50°C to 150°C   |  
        
| Resistance Range   | 0W to 400W   | 0W to 500 KW |  
        
| Characterizations   | ITS-90, IEC-751 (DIN “385”),Callendar-Van Dusen
 | Steinhart-Hart thermistorpolynomial, YSI 400 (2252 ohms)
 |  
        
| Temperature Accuracy (meter only)   | –200°C to 100°C: ±0.025°C  100°C to 400°C: ±0.05°C
 400°C to 800°C: ±0.1°C
 800°C to 962°C: ±0.15°C
 | 0°C to 50°C: ±0.005°C  50°C to 75°C: ±0.01°C
 75°C to 100°C: ±0.02°C
 |  
        
| Excitation Current   | 0.5 mA   | 5 mA   |  
        
| Operating Range   | 0°C to 40°C   |  
        
| Resolution   | 0.001°   |  
        
| Measurement Period   | 1 second   |  
        
| Digital Filter   | 1- to 60-second exponential filter   |  
        
| Probe Connection   | INFO-CON Connector   |  
        
| Communications   | RS-232 (Model 1522 also includes infrared interface)   |  
        
| Memory   | Stores 6 readings in “Hold” mode   | Logs 10,000 readings in “Auto Logging” mode; logs 100 readings in “Demand Logging” mode. Memory holds up to 25 data labels that may be attached to Demand Log readings or Auto Log data sets.   |  
        
| Display   | 6-digit, 7-segment LCD with 16x1 alphanumeric   |  
        
| Power   | Rechargeable nickel-metal-hydride batteries (AC adapter included)   |  
        
| Size   | 7.75" H x 4.2" W x 1.5" D (20 x 11 x 4 cm)   |  
        
| Weight   | 1 lb. (0.4 kg)   |  
        
| Probes from Hart   | Contact Hart for a wide variety of precision PRTs and thermistors   |  
        
| Calibration   | Accredited 10-point, NIST-traceable resistance calibration provided   |       The Models 1521 and 1522 are the first standards thermometers to fit into a battery-powered handheld package. They're as accurate as ±0.005°C!  You'll
 only find this level of accuracy in large desktop units that cost three times more.
 It's no wonder we call the 1521 the Little Lord Kelvin of thermometry.
      Fitting easily into your hand and weighing only 1 pound (0.4 kg), these thermometers can go anywhere.  And when they get there, you can have total confidence in the
 accuracy of your measurements.  The 1522 has the power of a full data logger,
 with memory to hold 10,000 readings.
      The 1521 and 1522 read both Pt-25 and Pt-100 RTDs as well as thermistors.PRTs and RTDs, with their wide temperature ranges and stabilities, have long been
 favored as temperature standards. From -200°C to 100°C, the 1521 reads PRTs accurately to
 ±0.025°C. Even at 800°C these are high-precision readouts, accurate to ±0.1°C.
      Ultra-stable thermistors offer excellent stability and even greater accuracies over a more narrow range—typically from about -10°C to 110°C. At temperatures below 50°C,
 these Handheld Thermometers read thermistors to ±0.005°C. Accuracy at 100°C is ±0.02°C.
      While a small number of handheld thermometers on the market offer 0.01° resolution, they fail to provide the accuracy necessary for the last digit to be meaningful. Hart’s Handheld
 Thermometers let you select resolution from 0.1° to 0.001° and offer the accuracy to support
 even 0.001° resolution.
      Of course, the 1521 and 1522 let you match the exact resistance-versus-temperature characteristics of an individually calibrated probe. This is true standards thermometry. Hart’s Handheld Thermometers
 read ITS-90, Callendar-Van Dusen, or Steinhart-Hart coefficients for maximum system accuracy.
 These are real algorithms, not approximating conversion methods or electronic look-up tables. If you
 want to use common industrial curves, RTDs can be read using the common DIN 43760 (IEC 751) curve
 and thermistors can be read using the YSI 400 curve.
 INFO-CON Connectors    
       
 
      Probes attach to the 1521 and 1522 using Hart’s own “INFO-CON” connector. The INFO-CON (partially based on U.S. Patent 5,857,777) allows you to change the probes you use without requiring
 you to reprogram your readout. A memory chip in the INFO-CON stores all the critical information
 about your probe, including its serial number, recall date, and calibration constants.
      When you connect your probe, the 1521 automatically recognizes whether you’re using an RTD or thermistor and downloads the calibration constants and type of conversion specific to your probe.
 It also checks the recall date stored in the INFO-CON to verify it has not expired. To dedicate a single
 probe to your readout, disable the password-protected interchangeability function and your thermometer
 will read only the probe you specify.
      Forget entering calibration constants yourself, and don’t worry about the mistakes that can so easily occur during that process. You don’t even need to select your sensor type. It’s all stored in the INFO-CON.
 Just plug in your probe and you’re ready to take readings.  It doesn’t get any easier.
      Information is loaded into the memory of the INFO-CON by Hart when you purchase a probe or have aprobe recalibrated by Hart. Alternatively, you may load your own information into an INFO-CON through the
 Handheld Thermometer or through Model 9934 LogWare.
      If you’d like to use a Hart Handheld Thermometer with probes you already own, no problem!  Spare connectors are available.  They easily connect to your probes, and you can program them yourself.
 Model 1521 LLK       The 1521 Little Lord Kelvin uses a menu system for convenient access to all functions. Calibration and sensorprogramming functions are password protected to help prevent unauthorized access.
      “Min” and “Max” functions store the lowest and highest readings since the last reset. The “Hold” function freezes and stores the current reading (up to six may be stored) for later recall. And the “Delta”
 function computes the difference between the current reading and a reference value, which may
 be recorded at any time.
      Each thermometer comes complete with rechargeable nickel-metal-hydride batteries, an AC adapter/charger, an RS-232 cable for connecting to your PC, and a spare INFO-CON connector.
 Every unit also includes a NIST-traceable calibration with actual resistance measurements for your
 individual meter at ten point s- four representing typical RTD values and six representing typical thermistor values.
 Model 1522 LLL      The Model 1522 Little Lord Logger has all the power and great features of the 1521 plus the ability to log data.  Two data acquisition modes are included.
      In “Auto Logging” mode, the 1522 can store up to 10,000 measurements at user-selectedintervals, including the value, unit of measure, date, and time of each measurement.  If you need
 more than one data set, stop recording any time and record as many sets as you like up to a total
 of 10,000 values. Once the 10,000 value limit is reached, recording stops, so data is never lost unless
 you tell the 1522 to clear its log.
      The 1522 also holds as many as 25 data labels in its memory so that each set of data can be uniquely tagged.  Simply select one of the 25 labels you’ve created before recording data.
 This label is then recorded with each measurement.
      In “Demand Logging” mode, up to 100 individual measurements can be recorded, each one tagged withone of the 25 data labels.  Whether you need a lot of measurements from one source or single
 measurements from many sources, the 1522 is a powerful data recording tool.
      With Hart’s 9934 LogWare software, data management is easy.  Data sets gathered remotely through the 1522 can be easily downloaded to a PC either as a single file or as individual files for each
 data set.  Link the LLL to your PC through a serial cable or its IrDA port to send data as ASCII or binary files.
 View the data, graph it, or apply alarms. With LogWare you can record data in real time either from a
 1522 or 1521 Thermometer.
   |  
					
    
    
				 |  |