                    Hart Scientific 9140 Dry-Well Calibrator
  
  
    | 
          
      
                	 Item Number: 9140 
                      	
                      Manufacturer: Hart Scientific 
                               
      	    Manufacturer Part No: 9140 
    	           
                                 
              
          Product Options
          
							* denotes required field 
								Hart Scientific 9140 Insert Options*
									
										You must select an option for 'Hart Scientific 9140 Insert Options'. 
									 
								 
							 
								NIST Traceable Calibration*
							 
						 
         
            
							 * Whole number only
						               
          	
                  
		      
     | 
    
                              
                                 |     
   
    
    
      Hart Scientific 9140 Dry-Well Calibrator 
The 9140 has a temperature range of 35 C to 350 C, and it reaches its maximum temperature in 12 minutes. At six pounds, it’s small enough to easily carry in one hand. It’s truly a unique innovation in dry-wells.   
The unit has a stability of +/-0.05 C or better and a uniformity of at least 0.4 C in the largest-diameter wells and 0.1 C in the smaller wells. Despite its small size, this unit performs.   
Use the display, calibrated to +/-0.5 C, as your reference, or use an external thermometer for maximum calibration accuracy. With three removable inserts to choose from, the 9140 is as versatile as it is fast. 
Features: 
- Lightweight and very portable 
 
- Accuracy to +/-0.25 C  
 
- RS-232 and Interface-it software included  
 
- Easy to recalibrate  
 
- The instrument features:
 -Rapid heating and cooling -Interchangeable multiple hole aluminum probe sleeves -Convenient hand strap -RS-232 interface capability  
- Built in programmable features include:
 -Temperature scan rate control -Temperature switch hold -Eight Setpoint memory -Adjustable readout in C or F 
 
Specifications:
 
    
     | 
   
   
						
							
								
		
											
		   
		
	  
	
	  
	  
	  
	  
			   
	  
	  
		If you have been using dry-well calibrators for field work, you know there is a lot more to a dry-well than its temperature range and stability. Size, weight, speed, convenience, and software are also significant.
	   
	   
	 
								 
   | 
		
											
		   
		
	  
	
	  
	  
	  
	  
			   
	  
	  
		If you have been using dry-well calibrators for field work, you know there is a lot more to a dry-well than its temperature range and stability. Size, weight, speed, convenience, and software are alsosignificant.
	   
	   
	 
								 
   | 
							 
						 
		
                 
                
                
                
                
            
					 
        
        
    
				 
    
					
    
    
				 
 | 
			 
		  |