                    Hart Scientific 9102S Dry Block Calibrator
  
  
    | 
          
      
                	 Item Number: 9102S-156 
                      	
                      Manufacturer: Hart Scientific 
                               
      	    Manufacturer Part No: 9102S-156 
    	           
                                 
              
          Product Options
          
							* denotes required field 
								Hart 9102S Insert Options 1*
									
										You must select an option for 'Hart 9102S Insert Options 1'. 
									 
								 
							 
								Hart 9102S Insert Options 2*
									
										You must select an option for 'Hart 9102S Insert Options 2'. 
									 
								 
							 
								Hart 9102S Additional Inserts
							 
								Hart 9102S Carry Case Option*
							 
								Hart 9102S Calibration Options*
							 
						 
         
            
							 * Whole number only
						               
          	
                  
		      
     | 
    
                              
                                 |     
   
    
    
      Hart Scientific Model 9102S Dry Block Calibrator        Hart's new line of portable dry-wells is incredible.  They're the smallest, lightest and most portable dry-wells in the world. For work in the temperature range of -10 C to 122 C, Hart's Model 9102 HDRC dry-well is another first in the industry.        This new dry-well is only 3.25 inches high and 6 inches wide, achieves temperatures as low as -10 C, is NIST-traceable and is accurate to ±0.5 C. The Model 9102 HDRC is excellent for dial gauges, digital thermometers, bulb switches and other sensors that need calibration below ambient. It's perfect for ISO-9000 quality programs because it's NIST-traceable.        The 9102 dry-well redefines portability and speed. You can take it  anywhere you need to go, and when you get there you won't have  to read a magazine while you wait for it to reach its set-point temperature.             It has two wells so you can use one for a reference thermometer to increase accuracy. Both wells are 1/2 inch in diameter, and each has inserts available for almost any sensor size.  The 9102 also has a battery pack option that gives you approximately four hours of field use when AC poweris unavailable.    Features:  
- 
14 F to 252 F (-10 C to 122 C) 
 
- 
Weighs Only 4 Lbs. 
 
- 
Accuracy of +/-0.9 F (14 F to 252 F) 
 
- 
Two Wells - One for a Reference Thermometer to Increase Accuracy 
 
- 
Stability of +/-0.36 F
  
Technical Specifications:   
  
| Range:  | 
14 F to 252 F (-10 C to 122 C)  | 
 
| Accuracy:  | 
14 F to 212 F: +/-0.9 F (-10 C to 100 C: +/-0.5 C)   212 F to 252 F: +/-1.8 F (100 C to 122 C: +/-1.0 C)  | 
 
| Stability:  | 
+/-0.36 F (±0.2 C)  | 
 
| Heating Times:  | 
Ambient to 212 F (100 C): 10 Minutes  | 
 
| Stabilization:  | 
5 Minutes  | 
 
| Cooling Times:  | 
Ambient to 32 F (0 C): 10 Minutes  | 
 
| Well Depth:  | 
4 inches (102 mm)  | 
 
| Removable Inserts:  | 
Available from 1/16" (1.6 mm) to 7/16" (11.1 mm)  [1/4" (6.4 mm) and 3/16" (4.8 mm) Included]  | 
 
| Power:  | 
115 VAC (±10%) to 230 VAC (±10%), 50/60 Hz  | 
 
| Size:  | 
3.25"H x 6" W x 6.75" D (83 x 152 x 171 mm)  | 
 
| Weight:  | 
4 lb. (1.8 kg)  | 
 
| Certification:  | 
Includes 6-Point, NIST-Traceable Certificate   of Calibration with Dataat the Following Points:   -10 C, 25 C, 50 C, 55 C, 100 C and 122 C  | 
 
 
  
 
 
  
     | 
   
   
		
                 
                
                
                
                
            
					 
        
        
    
				 
    
					
    
    
				 
 | 
			 
		  |