Ametek Jofra CTC-140A Dry Block Calibrator (-17 TO 140 C)
|
|
Item Number: CTC-140A
Manufacturer: Ametek (JOFRA)
Manufacturer Part No: CTC-140A
Product Options
* denotes required field
Ametek CTC Power Supply Selection (Pick One)*
Ametek CTC Dry Block Insert Selection (Pick One)*
NIST Traceable Calibration*
Ametek CTC Hard Carry Case Selection (Optional)*
Do you need to Order Spare Inserts? Answer Yes and We will Contact You*
|
Ametek Jofra CTC-140 A Dry Block Temperature Calibrator

The Ametek CTC-140A Heats & Cools!
The
new Ametek CTC-140 A dry block calibrator covers the temperature scale
in the high range from -17 TO 140 C / 572 to 284F having an excellent
stability of 0.05 C / 0.09 F. To be able to do calibration jobs in the
shortest possible time the calibrator is quick to both heat up and cool
down. Combining these abilities with the well-known auto stepping
function makes it a very time saving feature.
The CTC series is designed for both on-site and maintenance shop
use.The applications are generally critical process control but can
vary based on calibration and testing requirements. The user interface
is easy and intuitive.One-key-one-function gives you quick access to
time saving features such as the switch test or the auto-stepping
function. All models feature a large, backlit LCD display panel, which
is easy-to-read even in well-lit areas. Units features an informative
display that provides icons and information regarding the status of the
CTC and the calibration in-progress. The JOFRA CTC series consists of
six different models that differ in temperature ranges and immersion
depths. All units offer similar features. A rugged, slim-line, aluminum
outer casing with diecast top and bottom protects the CTC series of
dry-block calibrators. For easy documentation and automatic
calibration, all units are delivered with RS232 serial communication
and AMECAL-LIGHT PC calibration software.
Six models-
The JOFRA CTC series consists of six different models which differ in
temperature range and immersion depth. All units offer similar features
and the large, backlit LCD display panel, which is easy-to-read even in
well-lit areas. A rugged, slim-line, aluminum outer casing with
die-cast top and bottom protects the CTC series of dry-blocks.
Model and temperature range:
CTC-140 A -17 to 140 C/-1 to 284 F
CTC-320 A 33 to 320 C/91 to 608 F
CTC-320 B 33 to 320 C/91 to 608 F (Deep Well)
CTC-650 A 33 to 650 C/91 to 1202 F
CTC-650 B 33 to 650 C/91 to 1202 F (Deep Well)
CTC-1200 A 300 to 1200 C/572 to 2200 F
Well - optimized for speed
- The special designed heating block profile reduces the mass so it
heats up and cools down very quickly. The design still offers good
stability and accuracy.
High flexibility -
You are not limited by fixed holes. Interchangeable insertion tubes are
used to match the diameter of your sensor-under-test. Also multihole
inserts are available.
Stability indicator -Clear audio and visual indication in the display when the calibrator is stable.
FEATURES:
- Interchangeable inserts
- Multi-hole insertion tubes
- Automatic switch test
- RS 232 and calibration software
- Multi information display
- Safty banana bushings
- Auto stepping
- Stability indicator
- Count down timer (shows when unit is stable)
- Programmable maximum temperature
- Fast simulation/training mode
- Re-calibration from keyboard
Easy-to-use - Intuitive
operation - All instrument controls may be performed from the front
panel. The heat source is positioned away from the panel. This design
helps to protect the operator. The main functions on the CTC series are
designed with one-key-one-function logic. This means that there are no
sub-menus or difficult to remember multiple keystrokes necessary to
access primary functions. The easy-to-read, backlit display features
dedicated icons, which help in identifying instrument conditions and
operational steps.
Set temperature - The Up and Down arrow keys allow the user to set the exact temperature desired with a resolution of 0.1 C or F.
Instrument setups
- The CTC series stores the complete instrument setup, including:
engineering units, stability criteria, resolution, display contrast,
slope (ramp) rate, auto step settings, and maximum temperature.
Automatic switch test
- Operators can save a lot of time using the automatic temperature switch
test function to find values for the Open and Close temperatures.
Additionally, this feature displays the hysteresis (deadband) between
the two points. The feature ensures a very high repeatability when
testing temperature switches. Simply press the SWITCH TEST key to activate
the function. Maximum temperature - From the setup menu, the user can select the maximum temperature limit for the calibrator. This function prevents damage to the sensor-under-test caused by the application of excessive temperatures.
Re-calibration/adjustments
- The CTC series has a very easy and straight forward procedure for
re-calibration/adjustment. There is no need fora screwdriver or PC
software. The only thing you need is a reliable reference thermometer.
Place this reference probe in the calibrator and follow the
instructions on the display.
Liquid filled sensors and switches - The
tall B models with an immersion depth of 190 mm / 7.5 in. are ideal for
calibration of liquid filled sensors. The specially designed non-linear
heating elements in the CTC-650B and the increased block mass provide a
very homogeneous temperature throughout the block. It is essential for
the quality of the calibration/test that the full length of the sensing
part of the sensor is exposed to the same temperature. Calibrate analog
reading devices or switches with very high repeatability.

Simplified calibration documentation All JOFRA CTC- instruments are supplied with RS232 computer interface and the calibration software AMECAL-LIGHT for on-line use. This WINDOWS ®-based software allows the user to customize his or her calibration routines. The software is easy to use so you do not have to be a programmer to configure your own calibration procedures. After calibration you can print out certificates that contain all necessary information for your ISO-9000 or similar quality systems. The ETC calibrator can also work with the larger AMECAL-TEMPERATURE software, which supports automatic calibration for all JOFRA dry-block calibrators equipped with an RS-232 serial data interface including the JOFRA DTI-1000 digital thermometer. For semi-automatic calibrations, the software also supports liquid baths,
ice points, or other dry-block heating and cooling sources. Using the
software's SCENARIO function allows for combining instruments in virtually any configuration.
SPECIFICATIONS:
|
Specs 23 C
|
CTC140A
|
CTC320A
|
CTC650A
|
CTC320B
|
CTC650B
|
CTC1200A
|
|
Min. Temp.
|
-17 C
-1 F
|
33 C
91 F
|
33 C
91 F
|
33 C
122 F
|
33 C
122 F
|
300 C
572 F
|
|
Max. Temp.
|
140 C
284 F
|
320 C
608 F
|
650 C
1202 F
|
320 C
608 F
|
650 C
1202 F
|
1205 C
2200 F
|
|
Heating Time
|
15 min.
|
4 min.
|
10 min.
|
20 min.
|
39 min.
|
45 min.
|
|
Cooling Time
|
100 C to
0 C
10 Min
|
320 C to 100 C
16 Min
|
650 C to 100 C
28 Min
|
320 C to 100 C
22 Min
|
650 C to
100 C
62 Min
|
1200 C to
300 C
120 Min
|
|
Accuracy
|
0.4 C
0.7 F
|
0.5 C
0.9 F
|
0.9 C
1.6 F
|
0.5 C
0.9 F
|
0.6 C
1.1 F
|
2.0 C
3.6 F
|
|
Stability
|
0.05 C
0.09 F
|
0.1 C
0.18 F
|
0.1 C
0.18 F
|
0.1 C
0.18 F
|
0.05 C
0.09 F
|
0.1 C
0.18 F
|
|
Immersion Depth
|
115 mm
4.5 in.
|
110 mm
4.3 in.
|
110 mm
4.3 in.
|
190 mm
7.5 in.
|
190 mm
7.5 in.
|
110 mm
4.3 in.
|
|
Insert Diameter
|
19 mm
3/4 in.
|
26 mm
1 in.
|
26 mm
1 in.
|
26 mm
1 in.
|
26 mm
1 in.
|
27 mm
1 in.
|
|
Size/Weight
|
9.5 x 5.5 x
12.8 in.
15.5 Lbs.
|
9.5 x 5.5 x 12.8 in.
11 Lbs.
|
9.5 x 5.5 x 12.8 in.
13 Lbs.
|
9.5 x 5.5 x 16.1 in.
15.3 Lbs.
|
9.5 x 5.5 x
16.1 in.
23 Lbs.
|
9.5 x 5.5 x
16.1 in.
26.5 Lbs.
|
All Calibrators include Test Leads, Power Cable, 1 Insert Tube (You Select), Manual, Factory Calibration Certificate, RS-232 Cable, AmeCal-Light Software, Insert Removal Tool
Additional Information
|
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
| |
|
|
|