Fluke 54 Series II B Thermometers
|
|
Item Number: Fluke 54 II B
Manufacturer: FLUKE
Manufacturer Part No: Fluke 54
Product Options
* denotes required field
NIST Traceable Calibration*
|
Fluke 54 Series II B
Data Logging
Digital Thermometer
Fluke 50-II Thermometer Family

The new Fluke 50 Series II contact thermometers offer
fast response and laboratory accuracy (0.05% + 0.3 C)
in a rugged, handheld test tool.
Features (All Models):
• Large Backlit Dual Display
• Relative Time Clock on MIN, MAX, and AVG
• Electronic Offset Function Improves Overall Accuracy
• Measures J, K, T, and E-types of Thermocouples
• Readout in C, F, or Kelvin (K)
• Splash and Dust Resistant Case
• Protected by Impact Absorbing Holster
• User-friendly Front Panel
• Sleep Mode Increases Battery Life to 1000 Hours
• Separate Battery Compartment
• 3 Year FLUKE Warranty
The Fluke 53 Series II and 54 Series II Also Include:
• Data Logging up to 500 Points of Data
• User Adjustable Recording Interval
• Also Read Type R, S, and N Thermocouples
• Real Time Clock Captures the Exact Time of Day when Events Occur
• Recall Function Allows Logged Data Review
• IR Communication Port Allows Data to be Exported
to Optional FlukeView™ Temperature
• PC Software for Further Analysis and Graphing


Technical Specifications:
| Accuracy:
|
J, K, T, E, and N-type:
|
| Above -100 C:
|
+/- [0.05% + 0.3 C (0.5 F)]
R and S-type: +/-[0.05% + 0.4 C (0.7 F)]
|
| Below -100 C:
|
J, K, E, and N-types:
+/-[0.20% + 0.3 C (0.5 F)]
T-type: +/-[0.50% + 0.3 C (0.5 F)]
|
| Display Resolution:
|
0.1 C / F / K < 1000°; 1C / F / K ³ 1000
|
| Measurement Range:
|
J-type: -210C to 1200C (-346F to 2192F)
K-type: -200C to 1372C (-328F to 2501F)
T-type: -250C to 400C (-418F to 752F)
E-type: -150C to 1000C (-238F to 1832F)
N-type: -200C to 1300C (-328F to 2372F)
R/S-type: 0C to 1767C (32F to 3212F)
|
| Temperature Scale:
|
ITS-90
|
| Applicable Standards:
|
NIST-175
|
| Operating Temp:
|
-10C to 50C (14F to 122F)
|
| Storage Temp:
|
-40C to 60C (-40F to 140F)
|
| Humidity:
|
0% to 90%; 0C to 35C (32F to 95F)
0% to 70%; 0C to 50C (32F to 122F)
|
| General Unit Weight:
|
400g (14 oz)
|
| Dimensions:
|
6.8” L x 3.4” W x 1.5” D
|
| Battery:
|
3 AA Batteries; Typical 1000-hour life
|
| Certification:
|
CE, CSA, TUV (Pending)
|
| Safety:
|
CSA C22.2 No. 1010.1 1992;
EN 61010 Amendments 1,2
|
Selection Guide:
| Feature
|
Model 54
|
Model 53
|
Model 52
|
Model 51
|
| T/C Types:
|
K,J,T,E,N,R,S
|
K,J,T,E,N,R,S
|
K,J,T,E
|
K,J,T,E
|
| Inputs:
|
Dual
|
Single
|
Dual
|
Single
|
| Time Stamp:
|
Time of Day
|
Time of Day
|
Relative
|
Relative
|
| Rugged Holster:
|
•
|
•
|
•
|
•
|
| Sealed Case:
|
•
|
•
|
•
|
•
|
| Backlit Display:
|
•
|
•
|
•
|
•
|
| MIN/MAX/AVG:
|
•
|
•
|
•
|
•
|
| Toolpak Option:
|
•
|
•
|
•
|
•
|
| Differential Temp:
|
•
|
No
|
•
|
No
|
| Data Logging:
|
• (500 Points)
|
• (500 Points)
|
No
|
No
|
| IR PC Interface:
|
•
|
•
|
No
|
No
|
Additional InformationClick for Fluke Thermometer Selection Guide
|
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
|
|
FlukeView Forms Version 2.0 Software with cable for Fluke 180 Series multimeters, Fluke 789 ProcessMeter, Fluke 50 Series, Fluke 80 Series, Fluke 45 DMM with Cable.
|
Fluke 51 Series II Thermometers, Single Input
|
Fluke 52 Series II Thermometers, Dual Input
|
Fluke 53 Series II B Data Logging Thermometers, Single Input
|
|
| |
|
|
|