Ametek Jofra ETC-125A Dry Block Calibrator (-10 to 125 Deg C)
|
|
Item Number: ETC-125A
Manufacturer: Ametek (JOFRA)
Manufacturer Part No: ETC-125A
Product Options
* denotes required field
Ametek ETC Power Supply Selection*
Ametek ETC Test Well Selection*
NIST Traceable Calibration*
Ametek ETC Carry Case Option*
|
Ametek Jofra ETC-125A
Dry Block Temperature Calibrator

The Ametek ETC could be the world's fastest Dry Block Calibrator!
The Ametek Jofra ETC Dry Block heats up by up to 100°C / 212°F
per minute and completes a full dual-point test in less than 10 minutes,
including stability time; timesavings at your fingertips! The ETC- series is
designed for field testing of temperature measurement devices. The small
size and light weight make it a perfect instrument to verify sensors in difficult
to reach places. All JOFRA ETC units have many of the same useful
and timesaving features offered in the more advanced JOFRA
dry-block series.
FEATURES:
Designed for people
who perform tests and verifi cations of temperature
sensing devices in the fi eld. This instrument is ideal when time is a critical
factor and the highest accuracy is not a critical factor.
Reduced size and weight
are important considerations because the unit is able to fi t into a tool box or
instrument carrying case and can be used for sensors that are difficult to access.
One-key-one-function user interface provides immediate access to setting
the temperature and the auto-step timesaving function. There is no need for
manipulation of sophisticated menus.
The Stability indicator provides
audible and visual prompts when
the temperature is stable. This
function also includes a 3 minute
countdown before the stable
condition.
|
Stainless steel and rubber side panels make the instrument suitable for many
years of faithful duty in an industrial environment.
Cooling and heating - ETC-125 A dry-block -
The ETC-125 A is a
simple yet effective tool for verifying temperature instruments that
also require references below ambient temperatures: e.g.
air-conditioning and cold counters. The predrilled holes allow the
use of an insertion tube in the largest bore. This increases the flexibility
to match many sensor-under-test sizes.
Easy-to-use, intuitive operation - All instrument controls are
accessed directly from the front panel. The main functions on the
ETC- series are designed with one-key-one-function logic. This
means that there are no difficult multiple keystrokes to remember
to access primary functions. The easy-to-read, backlit display features
dedicated icons, which help in identifying instrument conditions and
operational steps.
Set temperature -
The Up and Down arrow keys allow the user
to set the exact temperature desired with a resolution of 0.1°C or °F.
Stability indicator - The bold checkmark on the display indicates
that the calibrator has reached the desired set temperature and is stable.
The operator may change the stability criteria and establish a greater
level of confidence in the calibration results as desired. A convenient
countdown timer is activated three minutes before the unit reaches stability.
This prompts you to be prepared to record results.

Auto-stepping - This feature saves time. The operator may stay in
the control room, or another remote location, monitoring the output
from the sensor-under-test while the ETC- series calibrator is
placed in the process and automatically changes the temperature
using a programmed step value and rate. Up to 9 different temperature
steps may be programmed, including the hold time for each step.
This feature is also ideal for burning-in new sensors prior to installation;
this minimizes initial drift and allows for initial testing. It is also useful for
testing temperature data loggers.
Maximum temperature -
From the setup menu, you can select a
lower maximum tempe-rature limit for the calibrator. This function
prevents damage to the sensor-under-test caused by the application of
excessive temperatures.
Instrument setups - The ETC-series stores the complete instrument
setup, including: engineering units, stability criteria, resolu-tion, auto-step
settings, and maximum temperature.
Re-calibration/adjustments made easy - The ETC- series has a very
easy and straightforward procedure for re-calibration/adjustment. There is
no need for a screwdriver or PC software. The only thing you need is a
reliable reference thermometer. Place the probe in the calibrator
and follow the instructions on the display.

Simplified calibration documentation All JOFRA ETC- instruments
are supplied with RS232 computer interface and the calibration software
AMECAL-LIGHT for on-line use. This WINDOWS ®-based software allows
the user to customize his or her calibration routines. The software is easy
to use so you do not have to be a programmer to configure your own
calibration procedures. After calibration you can print out certificates
that contain all necessary information for your ISO-9000 or similar
quality systems. The ETC calibrator can also work with the larger
AMECAL-TEM-PERATURE software, which supports automatic calibration
for all JOFRA dry-block calibrators equipped with an RS-232 serial data
interface including the JOFRA DTI-1000 digital thermome-ter. For
semi-automatic calibrations, the software also supports liquid baths, ice points,
or other dry-block heating and cooling sources. Using the software's
»SCENARIO« function allows for combining instruments in virtually
any configuration.
|
SPECIFICATIONS:
|
AMETEK-JOFRA
DRY BLOCK MODELS
Spec's at 23°C
|
ETC 125 A
|
ETC 400 A
|
ETC 400 R
IR Calibrator
|
|
Minimum Temp
|
-10°C / -14°F
|
28°C / 82°F
|
28°C / 82°F
|
|
Maximum Temp
|
125°C / 257°F
|
400°C / 752°F
|
400°C / 752°F
|
|
Heating Time
|
ambient to
100°C / 212°F
11 minutes
|
ambient to
maximum
5 minutes
|
ambient to maximum
5 minutes
|
|
Instrument Weight
|
1.8 kg / 3.9 lb
|
1.6 kg / 3.5 lb
|
1.7 kg / 3.7 lb
|
|
Instrument Size LxWxH
|
172x72x182 mm / 6.8x2.8x7.2 in.
|
172x72x182 mm / 6.8x2.8x7.2 in.
|
172x72x182 mm / 6.8x2.8x7.2 in.
|
|
Stability
|
0.05°C / 0.09°F
|
0.15°C / 0.27°F
|
0.3°C / 0.54°F
|
|
Accuracy
|
0.5°C / 0.9°F
|
0.5°C / 0.9°F
|
0.5°C / 0.9°F
|
|
Immersion Depth
|
110 mm / 4.3 in.
|
105 mm / 4.1 in.
|
-
|
|
Reference Probe Port Size
|
-
|
-
|
3 mm hole for external reference probe
|
|
Dry Well Sizes ETC125A Type 01
|
12.5 - 8 - 6 - 4 mm
|
-
|
-
|
|
Dry Well Sizes ETC125A Type 02
|
1/2 - 3/8 - 1/4 - 5/32 in.
|
-
|
-
|
|
Dry Well Sizes ETC400A Type 11
|
-
|
1/16 - 1/8 - 5/32 - 1/4 - 3/16 in.
|
-
|
|
Dry Well Sizes ETC400A Type 12
|
-
|
1/16 - 3/16 - 3/8 - 1/4 - 1/8 in.
|
-
|
|
Dry Well Sizes ETC400A Type 21
|
-
|
2 - 3 - 4 - 4 - 6 mm
|
Additional InformationAmetek-Jofra ETC Dry Block Detailed PDF Brochure
|
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
| |
|
|
|